AVERÍAS EN AIRE ACONDICIONADO FUJI ELECTRIC

CÓDIGOS DE ERROR , AVERÍA Y MANUALES FUJI ELECTRIC

averias fuji electric

Seguridades en aire acondicionado Fuji electric

Está prohibido desmontar, puentear o desactivar de cualquier forma los dispositivos de seguridad y control durante su funcionamiento. El equipo de aire acondicionado Fuji electric es un aparato eléctrico y no debe utilizarse si no está en perfecto estado técnico. Toda avería o desperfecto que menoscabe o pueda mermar la seguridad debe ser subsanado inmediatamente por personal especializado. Las partes y los componentes defectuosos se sustituirán exclusivamente por recambios originales FUJI ELECTRIC.


Abrir(+) Cerrar (-)

Gire móvil para visualizar códigos de error


Models Indoor unit RS-9LA RS-12LA Outdoor unit RO-9LA RO-12LA
 

Models Indoor unit RS-9LA RS-12LA Outdoor unit RO-9LA RO-12LA

Trouble Display (primary)Detailed Trouble Display (by Test Button)Detailed Error Item
ErrorOperationTimerErrorOperationTimer
Serial Signal ErrorNormal1 sec blinkingSerial reverse signal error at operation start up0.1sec blinking0.5sec 2 timesNormal Serial Reverse Signal can not be received more than 10 seconds >>Releases when it becomes normal
Signal reverse signal error during operation0.1sec blinking0.5sec 3 timesNormal Serial Reverse Signal can not be received more than 7 sec (after receiving effective reverse transfer signal) >>Releases when it becomes normal
Serial forward signal error at operation start up0.1sec blinking0.5 sec 4 timesNormal Serial Forward Signal can not be received more than 10 sec >>Releases when it becomes normal
Serial forward signal error during operation0.1sec blinking0.5sec 5 timesNormal Serial Forward Signal can not be received more than 10 sec ( after receiving effective forward transfer signal) >>Releases when it becomes normal
Indoor unit Thermister error0.5sec 2 times0.1sec blinkingIndoor Temperature Thermister Open0.1sec blinking0.5sec 2 timesThermister detection value is open when AC plug is inserted >>Releases when value becomes normal
Pipe Thermister Open or Short0.1sec blinking0.5sec 3 timesThermister detection value is open or short when AC plug is inserted >>Releases when value becomes normal
Outdoor unit Thermister error0.5sec 3 times0.1sec blinkingDischarge Thermister Open or Short0.1sec blinking0.5sec 2 timesThermistor detection value is open or short >>Outdoor unit stops
Releases when it becomes normal
Heat Exchanger Thermister Open0.1sec blinking0.5sec 3 timesThermistor detection value is open >>Outdoor unit stops
Releases when it becomes normal
Outdoor Temperature Thermistor Open or Short0.1sec blinking0.5sec 4 timesThermistor detection value is open or short >>Outdoor unit stops
Releases when it becomes normal
Indoor unit control error0.5sec 4 times0.1sec blinkingForced Automatic SW welded0.1sec blinking0.5sec 2 timesForced Auto SW is ON for more than 10 seconds continuously >>Error is indicated while it is ON
Normal Operation other than error indition
Main Relay welded0.1sec blinking0.5sec 3 timesSerial Reverse Signal is received 1 min. after Main relay becomes OFF >>Error is indicated while serial reverse signal is input on normal operation Normal operation except error indication
Power interruption error0.1sec blinking0.5sec 4 times50/60Hz is not detected after 2 seconds of power ON. >>Error is indicated and unit is stopped
codigos de averia

Models Indoor unit RY-54FA RY-54UA Outdoor unit RO-54FA RO-54UA
 

Models Indoor unit RY-54FA RY-54UA Outdoor unit RO-54FA RO-54UA

averias fuji electric

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

  

Leave Comment

Tu dirección de correo electrónico no será publicada.

error: contenido protegido!!