Está prohibido desmontar, puentear o desactivar de cualquier forma los dispositivos de seguridad y control durante su funcionamiento. El equipo de aire acondicionado Fuji electric es un aparato eléctrico y no debe utilizarse si no está en perfecto estado técnico. Toda avería o desperfecto que menoscabe o pueda mermar la seguridad debe ser subsanado inmediatamente por personal especializado. Las partes y los componentes defectuosos se sustituirán exclusivamente por recambios originales FUJI ELECTRIC.


Abrir(+) Cerrar (-)

Gire móvil para visualizar códigos de error


Models Indoor unit RS-9LA RS-12LA Outdoor unit RO-9LA RO-12LA
 

Models Indoor unit RS-9LA RS-12LA Outdoor unit RO-9LA RO-12LA

Trouble Display (primary)Detailed Trouble Display (by Test Button)Detailed Error Item
ErrorOperationTimerErrorOperationTimer
Serial Signal ErrorNormal1 sec blinkingSerial reverse signal error at operation start up0.1sec blinking0.5sec 2 timesNormal Serial Reverse Signal can not be received more than 10 seconds >>Releases when it becomes normal
Signal reverse signal error during operation0.1sec blinking0.5sec 3 timesNormal Serial Reverse Signal can not be received more than 7 sec (after receiving effective reverse transfer signal) >>Releases when it becomes normal
Serial forward signal error at operation start up0.1sec blinking0.5 sec 4 timesNormal Serial Forward Signal can not be received more than 10 sec >>Releases when it becomes normal
Serial forward signal error during operation0.1sec blinking0.5sec 5 timesNormal Serial Forward Signal can not be received more than 10 sec ( after receiving effective forward transfer signal) >>Releases when it becomes normal
Indoor unit Thermister error0.5sec 2 times0.1sec blinkingIndoor Temperature Thermister Open0.1sec blinking0.5sec 2 timesThermister detection value is open when AC plug is inserted >>Releases when value becomes normal
Pipe Thermister Open or Short0.1sec blinking0.5sec 3 timesThermister detection value is open or short when AC plug is inserted >>Releases when value becomes normal
Outdoor unit Thermister error0.5sec 3 times0.1sec blinkingDischarge Thermister Open or Short0.1sec blinking0.5sec 2 timesThermistor detection value is open or short >>Outdoor unit stops
Releases when it becomes normal
Heat Exchanger Thermister Open0.1sec blinking0.5sec 3 timesThermistor detection value is open >>Outdoor unit stops
Releases when it becomes normal
Outdoor Temperature Thermistor Open or Short0.1sec blinking0.5sec 4 timesThermistor detection value is open or short >>Outdoor unit stops
Releases when it becomes normal
Indoor unit control error0.5sec 4 times0.1sec blinkingForced Automatic SW welded0.1sec blinking0.5sec 2 timesForced Auto SW is ON for more than 10 seconds continuously >>Error is indicated while it is ON
Normal Operation other than error indition
Main Relay welded0.1sec blinking0.5sec 3 timesSerial Reverse Signal is received 1 min. after Main relay becomes OFF >>Error is indicated while serial reverse signal is input on normal operation Normal operation except error indication
Power interruption error0.1sec blinking0.5sec 4 times50/60Hz is not detected after 2 seconds of power ON. >>Error is indicated and unit is stopped
codigos de averia

Models Indoor unit RY-54FA RY-54UA Outdoor unit RO-54FA RO-54UA
 

Models Indoor unit RY-54FA RY-54UA Outdoor unit RO-54FA RO-54UA

averias fuji electric

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

AÑADIR MODELO
 

  

Leave Comment

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

error: contenido protegido!!